Re-development of a water-play Splash Pad Area in the Catfish Row Art Park on Levee Street in downtown Vicksburg, Mississippi.  The scope of work includes, but is not limited to, formed concrete retaining walls, concrete paving, integral color concrete, flow-through water play system with LED lighting & associated pluming and electrical, drainage, aggregate surfacing, sod, limited irrigation repair, and ornamental iron handrails.

PUBLIC MESSAGE BOARD
Discuss questions with the owner/creator of this Listing.
GSR on 02-Mar-2018 8:53:02 AM CST
A few questions regarding the splash pad equipment & LED's: 1. Is the manifold required to be the splash pad manufacturers stainless steel manifold? Or will PVC be approved? 2. Are the solenoid valves required to be brass/bronze? Or will PVC/EPDM versions be approved? 3. Are the LED lights to be RGB or White? 4. Are the LED lights required to operate with sequence capabilities, or is the LED intended to be static light (on/off operation)? 5. Is the feature controller to be operated with sequence capabilities or single timer? Thanks
LandscapeServicesEH on 02-Mar-2018 12:28:39 PM CST
Please find the answer to your questions listed below: 1) The manifold used to operate the splash pad should be the specific manifold recommended by the particular Manufacturer of the Splash Pad System being included in the bid to operate the proposed system. Substitutions to the Manufacturer's Materials Specifications will not be allowed. 2) All Splash Pad Equipment and Materials components, including the Solenoid Valves, shall meet the specifications of the particular Manufacturer of the Splash Pad System that is being included in the bid. Substitutions to the Manufacturer's Materials Specifications will not be allowed. 3) The LED Lights should have RGBW capabilities. 4) The LED Lights should have the capability to be programmed to create a sequenced light display, as well as provide a static (on/off) display. 5) The Water Feature System Controller shall have the capability to operate as a touch-activated, timed supply, as well as a owner-modified sequenced supply. The system should timer capabilities. The sequences shall have the option to be programmed or random, based on the owner's prefrences.
UPDATE/ADDENDUM HISTORY
All updates/changes are listed below::
01-Mar-2018 1:24:35 PM CST
UPDATE: Due to Questions regarding Drawing File Sheet Size Formatting, all drawing files, Sheets L1.0 through L1.9 have been re-loaded to this website. The originally attached Zip File of the Drawing Files has been removed. All Drawing File Sheet should format at 100% on 22" x 34" paper.
19-Feb-2018 8:16:08 AM CST
18-Feb-2018 10:01:02 PM CST