Click Here for free registration
5000147922 PURCHASE OF PRESSURE TRANSMITTERS FOR JEFFERSON PARISH DEPARTMENT OF WATER Attachment: 50-00147922 MASTER COPY.pdf 
Louisiana > Jefferson Parish Government
Solicitation: 72596460

IMPORTANT ANNOUNCEMENTS

Bid Law Requirement Update: Act 406
Vendors will be required to submit certain documentation with bid submission, i.e. affidavits, proof of insurance, etc. These requirements will be outlined specifically in the instructions of each bid package. Vendors should continue to carefully read and respond accordingly per the requirements of the bid packages. These changes are pursuant Louisiana Public Bid Law more specifically, Act 406 of the 2016 Louisiana Legislative Regular Session. For the purposes of this communication, this change applies to Jefferson Parish Government bid solicitations only. For more information, please call Jefferson Parish Purchasing at 504-364-2678.

Electronic Bond Submission May Be Required
If the bid documents require a surety, vendors submitting responses to Jefferson Parish through this site must submit an electronic bond through the respective online clearinghouse bond management system(s). You may click the link below to use https://www.centralauctionhouse.com/central-bidding/bid-bonds

Bid Submittal Formats:

While this site accepts various file types, sizes and quantities, the preferred method for delivering all of the appropriate and required bid documents is one single scanned PDF file. Vendors submitting bids with multiple uploaded images/photos of bid responses are solely responsible for clarity. If uploaded images/documents are not legible, the vendors submission will be rejected. Please note all requirements in this SUBMITTAL package for electronic bid submission.

NOTICE:

TO RESPOND TO THIS SOLICITATION, PLEASE PRINT THE ENTIRE BID FORM INCLUDING BID INSTRUCTIONS. COMPLETE THE BID FORM AND ATTACH ANY SPECIFICATIONS OR ADDITIONAL REQUIRED DOCUMENTS. SCAN THE ENTIRE BID RESPONSE AND UPLOAD TO THE ONLINE BIDDING SITE. ENSURE THAT YOU HAVE REVIEWED ALL INSTRUCTIONS THAT APPLY TO THIS BID, AS THE REQUIREMENTS FOR BOND SUBMISSIONS HAVE CHANGED.

Listing Information/Advertisement
PURCHASE OF PRESSURE TRANSMITTERS FOR JEFFERSON PARISH DEPARTMENT OF WATER  

SUBMITTAL INFORMATION
Creator Username: SCHAMPAGNE
Submittal Privacy: Response Encryption
Started: 27-May-2025 12:00:00 PM CDT
Ends: 02-Jun-2025 11:00:00 AM CDT ( Expired )
History: 143 Views, Messages
Event Status: Archived event
Actions: Sign-In to Bid
Username:

Password:
Visitors: Visitors/Central Bidding Plan Holders
PUBLIC MESSAGE BOARD
Discuss questions with the owner/creator of this Listing.
UPDATE/ADDENDUM HISTORY
All updates/changes are listed below::
27-May-2025 1:49:21 PM CDT
ADDENDUM #1 HAS BEEN ADDED
 
BID HISTORY
Username Bid Amount Type Company name Bid Amount Bid Placed
TII123
For entire project Technology International, Inc. =SEALED= 02-Jun-2025 9:42:07 AM CDT
 
BID NO.:
5/27/2025
50-00147922
TECHNOLOGY INTERNATIONAL INC
1131 S INTERNATIONAL PKWY,
SUITE 2251
LAKE MARY FL 32746
Delivery: 0 Days
sbenbow
For entire project Spectrum Group, Inc. =SEALED= 02-Jun-2025 1:47:00 AM CDT
 
Jefferson Parish Purchasing Department 
200 Derbigny Street
General Government Building, Suite 4400
Gretna, LA  70053
Attn:  Stacey Champagne - Puchasing Specialist

Ref:  Bid No. 50-00147922
Delivery: 0 Days
miatlantic
For entire project Morgan Ingland =SEALED= 30-May-2025 8:02:48 AM CDT
 
NSF (YN) Available High performance differential pressure transmitter Code266DSH.F.S.S.B.2.A.1-V1.E6.L1....M5...N2..YN.H3266DSH- Span Limits / Base Accuracy F 0.4 and 40 kPa (4 and 400 mbar, 1.6 and 160 in. H2O) / Base accuracy 0.06%- Maximum Working Pressure (Static Pressure) S Standard Static- Diaphragm Material / Fill Fluid S AISI 316L ss / Silicone oil (NACE)- Process Flanges and Adapters Material / Connection B AISI 316L ss / 1/2 in. -14 NPT female through adapter (horizontal connection) (NACE)- Bolts Material / Gasket Material 2 AISI 316 ss / PTFE- Housing Material / Electrical Connection A Aluminum alloy (Barrel version) / 1/2 in. - 14 NPT- Output 1 HART and 4 to 20 mA - Advanced functionality- Vent and Drain Valve Material / Position V1 AISI 316L ss / On process axis (NACE)- Hazardous Area Certification E6 FM Approvals (USA) approval (XP, DIP, IS, NI, Type N)- Integral LCD L1 Digital LCD integral display with integrated keypad- Full Operating Instruction Manual Language M5 Instruction Manual in English- Configuration N2 Standard pressure = in. H2O / psi at 68 °F; Temperature=deg.F- Approval YN NSF/ANSI 61 Drinking Water Certified- Material Traceability H3 Inspection certificate EN 10204-3.1 of process wetted pa

NSF (YN) Available High performance gauge pressure transmitter Code266HSH.M.S.T.A.1-.E6.L1..B7..M5...N2..YN.H3266HSH- Sensor Span Limits / Sensor Overpressure / Base M 6 and 600 kPa (0.06 and 6 bar, 0.87 and 87 psi) / 14MPaAccuracy (140 bar, 2030psi) / Base accuracy 0.06%- Diaphragm Material / Fill Fluid S AISI 316L ss / Silicone oil (NACE)- Process Connection Material / Type T AISI 316L ss / 1/2 in. - 14 NPT male (NACE)- Housing Material / Electrical Connection A Aluminum alloy (Barrel version) / 1/2 in. - 14 NPT- Output 1 HART and 4 to 20 mA - Advanced functionality- Hazardous Area Certification E6 FM Approvals (USA) approval (XP, DIP, IS, NI, Type N)- Integral LCD L1 Digital LCD integral display with integrated keypad- Mounting Bracket Shape / Material B7 For horizontal or vertical mounting on pipe and wall / AISI 316L ss- Full Operating Instruction Manual Language M5 Instruction Manual in English- Configuration N2 Standard pressure = in. H2O / psi at 68 °F; Temperature=deg.F- Approval YN NSF/ANSI 61 Drinking Water Certified- Material Traceability H3 Inspection certificate EN 10204-3.1 of process wetted pa
 
Delivery: 0 Days
Bids Added by Agency/Owner